• ADT 780 Pressure Controller (69.230769230769%)

    ADT 780 Pressure Controller

ADT 780 Pressure Controller



• Pressure ranges from  vacuum to 3,000 psi (200 bar)

• Precision model accuracy of 0.005%RD + 0.005%FS

• Standard model accuracy of 0.02%FS

• HART Communication and Profibus PA

• Control stability of 0.003%FS

• Easy-to-use icon based user interface

 homepage | info@triwi-online.com | contact us data-sheet Catalog | Manual | Video pdf |  

Applications

The 780 Pressure Controller is considered to handle a very wide range of applications which may normally require a pressure calibrator. Built-in capability, includes current and voltage measurement capability, 24 volt loop power, HART® and Profibus PA communication, switch measurement capability, selectable analog output and much more.

Measurement Specifications

Model Number ADT780-1K ADT780-3K
Pressure range -14.5 to 1,000 psi   (-0.95 to 70 bar) -14.5 to 3,000 psi   (-0.95 to 200 bar)(1)
Control stability 0.003% FS
Precision (includes 1 year stability) See pressure range table
1 Year stability 0.01% FS standard accuracy sensors 0.005% FS precision accuracy sensors
Media clean  Gas
Over-range indication 103% to 120% (based on sensor)
Resolution 4, 5, 6, or 7 digits (user selectable)(2)
Pressure type Gauge, Absolute
Warm up time 15 minutes

Typical pressure settling time (within 0.003%FS)

20 seconds (10%FS pressure change   assuming 50ml test volume)
Measurement units Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C,   mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C,  mmH2O@20°C, cmH2O@20°C, mH2O@20°C, kg/m2,   kg/cm2, mtorr, torr, atm, lb/ft2, tsi, user selectable
Minimum control pressure(3) 0.0001 psi 0.001 psi

(1). Gas booster or HP gas supply required to reach 3,000 psi (200 bar). Booster ordered separatel.

(2). Digit resolution for precision model only.

(3). Dependent on pressure module.

 

Barometric Measurement Specifications

Sensor/Mode Gauge Absolute
ADT160A-02-CPXX N/A 40Pa(1)
ADT160A-01-APXXQ 3Pa(2) N/A

Barometer range (60~110)KPa, the accuracy is 40Pa (11Pa is optional)

(1). 40Pa uncertainty (k=2) includes calibration uncertainty, linearity and long term stability (< 30Pa per year). Barometer range of 60 to 120KPa.

(2). Combined linearity, hysteresis and repeatability. Add 3Pa when used in gauge mode. When using the ADT160A-01-APXXQ sensors with the ADT780 controller in gauge mode, regular zeroing will realign the barometric reading to provide the most accurate result.

 

Electrical Measure Specifications

Specification Range Resolution Accuracy
Volts DC -30 to 30 V 0.1 mV ±0.01% rdg + 1.5 mV
-300 to 300 mV 1 uV ±0.01% rdg + 15 uV
Current DC -30 to 30 mA 0.1 uA ±0.01% rdg + 1.5 uA
Switch test If the switch has detected voltage,   the range is from 3 – 24 V
DC 24V output 24V ± 0.24V, max 30 mA

 

Physical Specifications

Specification ADT780-1K & ADT780-3K
Power 100 – 240V,  50/60 Hz
Pressure ports G1/8 F
Storage temperature -20°C to 70°C
Operating environment 0-95% RH non-condensing
Display 7 inch (17.8 cm) color, touch screen   display
Weight 33 lbs (15 kg)
Dimensions(DWH) 16.5 x 17.3 x 5.2 inch (419 x 440 x   132 mm)
Mounting Standard desktop, optional rack mount
Shock 4G
Vibration 1G   10Hz~500Hz

 

Other Specifications

WiFi specifications 802.11 b, g, and n
Stability indicator User selectable
Typical slew rate Typically 20 seconds
Operating modes Control, measure, and vent
 
Display modes
Controller – show pressure indication and control 
Calibrator – shows pressure   indication, control, and electrical measurement
Localization English, Chinese (simplified), German,   Spanish, French, Italian, Portuguese, Russian, Japanese
Conformity CE
Calibration certification NIST-traceable certificate of   calibration with data included
Warranty 1 year

 

 

Electric Pump and Booster

ADT780-1K-EPUMP Electric Pump

Generate Vacuum to 1,000 psi(700bar) 
Built-in filter and liquid trap

Pressure range -13.5 to 1,080 psi (-0.95 to 75 bar)
Weight

69.6 lbs (31.6   kg)

Size(WHD) 17.3 X 9.3 X 21.7 inch   (440 X 235X 550 mm)
Power 100 to 240V
Media Air
Outlet port G   1/8F
Storage temperature -20°C to 70°C
Operating environment 0-90% RH   non-condensing
Mounting Standard   desktop, optional rack mount
Control operation 2   LED displays with pressure limit settings
Typical max pressure time Approx   2 min with ADT780 Controller

  

ADT780-3K-BST Booster 
3,000 psi (200bar) Gas booster specification

Minimum inlet pressure 300 psi (20 bar)
Out pressure range 300 to 3,600 psi (250 bar)
Inlet flow rate 500ml/min
Size (WHD) 17.8 X 7.3 X 23.9 inch   (451 X 185 X 607 mm)
Weight 74 lbs (33.6   kg)
Power 100 to 240V
Supply media Nitrogen or clean gas

 

The Range of ADT160A Intelligent Digital Pressure Modules

P/N Pressure Range Media Accuracy Pressure Rating Suggested Controller Compatibility Internal/ External Use
psia bar.a Burst Over Pressure

Precision Quartz Sensors[1]

AP45Q 0 to 45 3.0 G 0.005% rdg + 0.005% FS 3x 1.2x ADT780-1K only Both
AP100Q 0 to 100 7.0 G 0.005% rdg + 0.005% FS 3x 1.2x ADT780-1K only Both
AP400Q 0 to 400 28 G 0.005% rdg + 0.005% FS 3x 1.2x Both Both
AP500Q 0 to 500 35 G 0.005% rdg + 0.005% FS 3x 1.03x Both Both
AP1KQ 0 to 1,000 70 G 0.005% rdg + 0.005% FS 3x 1.1x Both Both
AP2KQ 0 to 2,000 140 G 0.005% rdg + 0.005% FS 3x 1.1x ADT780-3K only Both
AP3KQ 0 to 3,000 200 G 0.005% rdg + 0.005% FS 3x 1.1x ADT780-3K only Both

Standard Pressure Sensors

P/N Pressure Range Media Accuracy Pressure Rating Suggested Controller Compatibility Internal/ External Use
psig bar.g Burst Over Pressure
CP10 ±10 ±0.7 G 0.02% FS 3x 1.2x ADT780-1K only Both
CP15 ±15 ±1.0 G 0.02% FS 3x 1.2x ADT780-1K only Both
CP30 -15 to 30 -1 to 2.0 G 0.02% FS 3x 1.2x ADT780-1K only Both
CP50 -15 to 50 -1 to 3.5 G 0.02% FS 3x 1.2x ADT780-1K only Both
CP100 -15 to 100 -1 to 7.0 G,L 0.02% FS 3x 1.2x ADT780-1K only Both
CP300 -15 to 300 -1 to 20 G,L 0.02% FS 3x 1.2x Both Both
CP500 -15 to 500 -1 to 35 G,L 0.02% FS 3x 1.2x Both Both
CP600 -15 to 600 -1 to 40 G,L 0.02% FS 3x 1.2x Both Both
CP1K -15 to 1,000 -1 to 70 G,L 0.02% FS 3x 1.2x Both Both
CP2K -15 to 2000 -1 to 140 G,L 0.02% FS 3x 1.2x ADT780-3K only Both
CP3K -15 to 3,000 -1 to 200 G,L 0.02% FS 3x 1.2x ADT780-3K only Both
CP5K -15 to 5000 -1 to 350 G,L 0.02% FS 3x 1.2x N/A External
CP10K -15 to 10,000 -1 to 700 G,L 0.02% FS 2x 1.2x N/A External

[1] Contact Additel for other range options.
**Low pressure sensors (ADT160A-XX-DPX) available for low pressure and differential pressure measurement. Also available for low pressure control (gauge mode only). Ranges from ±1 inH20 (2.5 mbar) to 300 inH2O (700 mbar).